Version: 10.2.1c and 10.2.1c SP3 |
| Fiber Manager Configuration > Configure/Upgrade Circuit Manager > Circuit Manager Step 4: Configure Tables |
Use the following information to configure tables necessary for Circuit Manager functionality.
Alias: Circuit Component
Model Name: FIBERCIRCUITCOMPONENTS
Field Model Name: None
Object Info (Autoupdater): None
Field Info (Autoupdater): None
Field Display:
Primary Display Field Display Name Object None Primary Display Field ObjectID
| Field | Data Type | Default Value | Domain | Length/Precision |
|---|---|---|---|---|
| CircuitStatus Alias: Status |
Text | Fiber Circuit Status | 50 | |
| FiberLambda Alias: Wavelength |
Double | |||
| FiberCircuitGraph Alias: Graph |
Text | 5000 |
Using the following five tables, ensure that ALL of these settings are in place for the F_CIRCUIT table:
Alias: Circuit
| Field | Data Type | Default Value | Domain | Length/Precision |
|---|---|---|---|---|
| CircuitLength Alias: Length (ft) |
Double | |||
| CircuitName Alias: Name |
Text | 255 | ||
| CircuitStatus Alias: Status |
Text | Fiber Circuit Status | 50 | |
| CircuitType | Text | Fiber Circuit Type | 255 | |
| FiberCircuitGraph Alias: Graph |
Text | 5000 | ||
| FiberCircuitHeaderClass | Text | 255 | ||
| FiberCircuitHeaderGlobalID | Guid | |||
| FiberCircuitTraceStyle | Long Integer | |||
| FiberLambda Alias: Wavelength (nm) |
Double | |||
| GlobalID | Global ID | |||
| ObjectID | Object ID |
Assign the following model names:
Class Model Names: FIBERCIRCUITTABLE, FIBEROBJECT
Field Model Names:
| Field | Field Model Name |
|---|---|
| CircuitChannel | CIRCUITCHANNEL |
| CircuitType | CIRCUITTYPE |
| CircuitLength | CALCULATEDFIBERCIRCUITLENGTH |
| CircuitName | FIBERCIRCUITNAME |
| CircuitStatus | FIBERSTATUS |
| FiberCircuitGraph | FIBERCIRCUITGRAPH |
| FiberCircuitTraceStyle | FIBERCIRCUITTRACESTYLE |
| FiberCircuitHeaderClass | FIBERCIRCUITHEADERCLASS |
| FiberCircuitHeaderGlobalID | FIBERCIRCUITHEADERGLOBALID |
| FiberLambda | FIBERLAMBDA |
| FiberParent | FIBERPARENT |
| GlobalID | GLOBALID |
| ThisFiberClassModelName | THISFIBERCLASSMODELNAME |
Create the following object autoupdaters on the table:
Object Info (Autoupdaters):
| Feature Property Display | Autoupdater |
|---|---|
| On Feature Update | ArcFM Fiber Calculated Circuit Length |
| On Feature Delete | ArcFM Fiber Object Deleted |
Create the following field autoupdaters:
Field Info (Autoupdaters):
| Field Name | On Feature Create | On Feature Update |
|---|---|---|
| CreationUser | ArcFM Login User Name | |
| CreationDate | ArcFM Current Date | |
| LastUser | ArcFM Login User Name | |
| DateModified | ArcFM Current Date |
Assign a primary field to display:
Field Display:
| Primary Display | Field |
|---|---|
| Display Name Object | None |
| Primary Display Field | CircuitName |