Configuring Responder/Smart Grid
Clean Up Regions

Version: 10.1

Resource Center Home

This tool removes any record in the RX_REGION_ASSIGNMENTS table that references an obsolete OID for the Regions feature class. This step needs to be performed ONLY in the following instances:

If any of the above are true, follow the steps below to remove any obsolete rows in the RX_REGION_ASSIGNMENTS tabel.

  1. Start the Responder Windows Service. You may also use the Prediction Console. Double-click Miner.Responder.PredictionServices.exe and skip to step 5.
  2. Open Responder Service Configuration.
  3. Select the Prediction Services tab and ensure at least one instance of Prediction Services is running.
  4. Select Console.
  5. Enter ONE of the following commands and click Send. Enter the command EXACTLY as shown.
    rm cleanup
    
    region_mode cleanup
    
 

For more information about the commands available in the Prediction console, see the Responder Service Commands page.

 


Send Comment to documentation@schneider-electric.com