Version: 10.2.1d and 10.2.1d SP2 |
Appendix > Gas Distribution Data Model Overview > Pipes and Maintenance Overview > GasPressureSystem |
The gas pressure system is a continuous flow system with common Maximum Allowable Operating Pressure (MAOP) and System Operating Pressure (SOP) bound by the Town Border Station, Regulator Station, dead end, or a normally closed valve.
Subtypes: None
Associations: GasSystem, EmergencyIsolationsSystem
Model Names: None
Attributes:
Comments: text - User and designer comments.
GasSystemObjectID: long integer - ObjectID of associated GasSystem.
Hyperlink: text -Used to store a hyperlink path via standard Esri hyperlinking functionality.
MAOPEntered: double - Maximum Allowable Operating Pressure, in any unit of measure.
MAOPStandard: double - Derived field displaying calculated standard Maximum Allowable Operating Pressure.
MAOPUnitOfMeasure: text - MAOP standard unit of measure; examples include psi, iwc, etc.
SOPEntered: double - System Operating Pressure, in any unit of measure.
SOPRange: text - Range of System Operating Pressure.
SOPStandard: double - Derived field displaying calculated standard System Operating Pressure.
SOPUnitOfMeasure: text - Standard unit of measure for System Operating Pressure.