ArcFM Solution Configuration Guide
GasPressureSystem

Version: 10.2.1d and 10.2.1d SP2

Resource Center Home

The gas pressure system is a continuous flow system with common Maximum Allowable Operating Pressure (MAOP) and System Operating Pressure (SOP) bound by the Town Border Station, Regulator Station, dead end, or a normally closed valve.

Subtypes: None

Associations: GasSystem, EmergencyIsolationsSystem

Model Names: None

Attributes:

Comments: text - User and designer comments.

GasSystemObjectID: long integer - ObjectID of associated GasSystem.

Hyperlink: text -Used to store a hyperlink path via standard Esri hyperlinking functionality.

MAOPEntered: double - Maximum Allowable Operating Pressure, in any unit of measure.

MAOPStandard: double - Derived field displaying calculated standard Maximum Allowable Operating Pressure.

MAOPUnitOfMeasure: text - MAOP standard unit of measure; examples include psi, iwc, etc.

SOPEntered: double - System Operating Pressure, in any unit of measure.

SOPRange: text - Range of System Operating Pressure.

SOPStandard: double - Derived field displaying calculated standard System Operating Pressure.

SOPUnitOfMeasure: text - Standard unit of measure for System Operating Pressure.

 

 


Send Comment to ArcFMdocumentation@schneider-electric.com