ArcFM Server Developer Guide
Get Network EID

Version: 10.2.1c and 10.2.1c SP3

Resource Center Home

The GetNetworkEID tool allows you to retrieve EID values for features. These values may be required by some parameters in the Electric, Gas, and Water tracing tools.

http://dufek/ArcGIS/rest/services/Gas/MapServer/exts/ArcFMMapServer/GetNetworkEID?

          modelName=VALVE&

          point={x%3A2213252.324%2C+y%3A397683.849}&

          tolerance=10&

          f=pjson

 

Set the parameters and click GetNetworkEID to start the search. The following table describes the available parameters as well as valid and default values. 

The point field accepts an XY value as shown in the image above as well as a value in json format. For example: {x:2213252.324, y:397683.849}

This format also allows you to indicate a spatial reference. For example:

{x:2213252.324, y:397683.849, spatialReference:{WKID:4326}}

Property

Description

Valid Values

URI Values

Default Value

modelName

Model name that identifies the feature class (e.g., VALVE).

Any valid class model name

Null

point

An XY value indicating the point at which you want to search for features.

Any valid XY location on the map

 

Null

tolerance

A numerical value indicating in map units the search tolerance for the search.

Any positive whole number

Null
format

Select the format used to return results.

json, html json, html json

 

 

 


Send Comment to ArcFMdocumentation@schneider-electric.com