The following domains are required for Network Adapter configuration and may already exist in your database. Ensure all domains listed below exist in your database before continuing to the next step. The domains below display the coded values configured in the Minerville sample data. Your coded values may vary.
Domain Properties:
Field Type = long integer
Domain Type = coded values
Split Policy = duplicate
Merge Policy = default value
Coded Values:
Code
Description
100
100 KVAR
150
150 KVAR
200
200 KVAR
300
300 KVAR
Domain Properties:
Field Type = text
Domain Type = coded values
Split Policy = default value
Merge Policy = default value
Coded Values: Add all consumption types that have been defined in the DMS catalog to this domain. Refer to DMS documentation for more information.
Domain Properties:
Field Type = text
Domain Type = coded values
Split Policy = duplicate
Merge Policy = default value
Coded Values:
Code
Description
D
Delta
W
Wye
Domain Properties:
Field Type = text
Domain Type = coded values
Split Policy = duplicate
Merge Policy = default value
Coded Values:
Code
Description
1/0
1/0 AWG
1000
1000 MCM
2
2 AWG
2/0
2/0 AWG
250
250 MCM
3/0
3/0 AWG
300
300 MCM
336
336 MCM
350
350 MCM
4
4 AWG
4/0
4/0 AWG
500
500 MCM
556
556 MCM
6
6 AWG
750
750 MCM
477
477
Below is an example of how you might set up this domain. The codes and values will be specific to your utility. The Description field holds the values that the user will see in the dropdown menu. The example below reflects how this domain appears in the Minerville sample data.
Domain Properties:
- Field Type = long integer
- Domain Type = coded values
- Split Policy = duplicate
- Merge Policy = default value
Coded Values:
Code
Description
120
4.16 kV Grounded Y
160
7.2 kV Grounded Y
210
12.5 kV Grounded Y
230
13.2 kV Grounded Y
270
13.8 kV Grounded Y
340
24.9 kV Grounded Y
380
34.5 kV Grounded Y
80
2400 V Delta
110
4160 V Delta
150
7200 V Delta
260
13800 V Delta
Below is an example of how you might set up this domain. The codes and values will be specific to your utility. The Description field holds the values that the user will see in the dropdown menu. The example below reflects how this domain appears in the Minerville sample data.
Domain Properties:
Field Type = long integer
Domain Type = coded values
Split Policy = duplicate
Merge Policy = default value
Coded Values:
Code
Description
10
120 Volts
20
120/208 Volts
30
120/240 Volts
40
240/480 Volts
50
277/480 Volts
60
480 Volts
120
4.16 kV Grounded Y
160
7.2 kV Grounded Y
210
12.5 kV Grounded Y
230
13.2 kV Grounded Y
270
13.8 kV Grounded Y
340
24.9 kV Grounded Y
380
34.5 kV Grounded Y
80
2400 V Delta
110
4160 V Delta
150
7200 V Delta
260
13800 V Delta
Domain Properties:
Field Type = text
Domain Type = coded values
Split Policy = default value
Merge Policy = default value
Coded Values:
Code
Description
None
None
Upstream
Upstream
Downstream
Downstream
Domain Properties:
Field Type = long integer
Domain Type = coded values
Split Policy = duplicate
Merge Policy = default value
Coded Values:
Code
Description
1
1 A
2
2 A
3
3 A
6
6 A
8
8 A
10
10 A
15
15 A
20
20 A
25
25 A
30
30 A
40
40 A
50
50 A
65
65 A
80
80 A
100
100 A
140
140 A
200
200 A
Domain Properties:
Field Type = text
Domain Type = coded values
Split Policy = duplicate
Merge Policy = default value
Coded Values:
Code
Description
H
H Link
K
K Link
N
N Link
T
T Link
X
X Link
200
200
Domain Properties:
Field Type = text
Domain Type = coded values
Split Policy = duplicate
Merge Policy = default value
Coded Values:
Code
Description
AAC
All Aluminum Conductor
ACSR
All Aluminum Steel Reinforced
AL
Aluminum
CU
Copper
CUWD
Copper Weld
HDCU
Hard Drawn Copper
SDCU
Soft Drawn Copper
STEL
Steel
NA
Not Applicable
Domain Properties:
Field Type = text
Domain Type = coded values
Split Policy = duplicate
Merge Policy = default value
Coded Values:
Code
Description
1/0
1/0 AWG
1/3
1/3 Concentric Neutral
1000
1000 MCM
2
2 AWG
2/0
2/0 AWG
250
250 MCM
3/0
3/0 AWG
300
300 MCM
336
336 MCM
350
350 MCM
4
4 AWG
4/0
4/0 AWG
500
500 MCM
6
6 AWG
750
750 MCM
FULL
Full Concentric Neutral
NA
Not Applicable
Domain Properties:
Field Type = long integer
Domain Type = coded values
Split Policy = duplicate
Merge Policy = default value
Coded Values:
Code
Description
1
Closed
0
Open
2
Not Applicable
Domain Properties:
Field Type = long integer
Domain Type = coded values
Split Policy = duplicate
Merge Policy = default value
Coded Values:
Code
Description
0
Other
1
Company
Domain Properties:
Field Type = long integer
Domain Type = coded values
Split Policy = duplicate
Merge Policy = default value
Coded Values:
Code
Description
7
ABC
6
AB
5
AC
4
A
3
BC
2
B
1
C
The Priority field on the Transformer feature class uses this domain. DMS requires this domain be assigned to the Priority field. It indicates the priority level with 0 being the highest priority and 5 being the lowest. This domain is required by DMS and does not appear in the sample data.
Domain Properties:
Field Type = long integer
Domain Type = coded values
Split Policy = default value
Merge Policy = default value
Coded Values:
Code
Description
0
Highest priority
1
2
3
4
5
Lowest priority
Network Adapter maps this domain (and the Transformer Bank Low Side Configuration domain) to the Winding Code domain in MultiSpeak. It is critical that the values be created as outlined below. If you use the Winding Code domain, the Transformer Bank High Side Configuration domain is not needed.
Domain Properties:
Field Type = text
Domain Type = coded values
Split Policy = duplicate
Merge Policy = default value
Coded Values:
Code
Description
D
Delta
OD
Open Delta
OY
Open Wye
LG
Single Phase Line - Ground
LL
Single Phase Line - Line
Y
Wye
Domain Properties:
Field Type = text
Domain Type = coded values
Split Policy = duplicate
Merge Policy = default value
Coded Values:
Code
Description
BR
Breaker
BY
Bayonet Fuse
DW
Dry Well Canister
NONE
None
OIL
Oil Immersed
WL
Weak Link
Network Adapter maps this domain (and the Transformer Bank High Side Configuration domain) to the Winding Code domain in MultiSpeak. It is critical that the values be created as outlined below. If you use the Winding Code domain, the Transformer Bank Low Side Configuration domain is not needed.
Domain Properties:
Field Type = text
Domain Type = coded values
Split Policy = duplicate
Merge Policy = default value
Coded Values:
Code
Description
3D
3 Wire Delta
4D
Wire Delta
Y
Wye
Domain Properties:
Field Type = long integer
Domain Type = coded values
Split Policy = duplicate
Merge Policy = default value
Coded Values:
Code
Description
10
10 kva
15
15 kva
25
25 kva
38
37.5 kva
50
50 kva
75
75 kva
100
100 kva
112
112 kva
150
150 kva
167
167 kva
225
225 kva
250
250 kva
300
300 kva
333
333 kva
500
500 kva
750
750 kva
1000
1000 kva
1500
1500 kva
2000
2000 kva
2500
2500 kva
Create this domain only if you are using a MultiSpeak data model. If you create this domain, the Transformer Bank High Side Configuration and Transformer Bank Low Side Configuration domains aren't necessary.
Domain Properties:
Field Type = text
Domain Type = coded values
Split Policy = duplicate
Merge Policy = default value
Coded Values:
Code
Description
Y-Y
Y-Y
D-Y
D-Y
Grounded Y-D
Grounded Y-D
Ungrounded Y-D
Ungrounded Y-D
Open Y-D
Open Y-D
D-D
D-D
Y-Y Grounded Imp
Y-Y Grounded Imp
Y-Y 3 Phase Core Type
Y-Y 3 Phase Core Type
D-D one
D-D one
Y-Y-D Ground
Y-Y-D Ground
Y-D one
Y-D one
D-Y open
D-Y open