Configuring Responder
Network Adapter - Exception Management

Version: 10.2.1c and 10.2.1c SP3

Resource Center Home

During export, Network Adapter validates some aspects of the data and reports any invalid features. You can control how Network Adapter reacts to specific errors. You can have Network Adapter report the data error and continue, ignore the error, or terminate the export. By default, all data errors are reported and Network Adapter continues the export. Follow the steps below to modify the functionality.

  1. Browse to and open NetworkAdapter.exe.config at the following location: Program Files (x86)\ArcFM Solution\Bin. Open this file using any text editor or XML editor.
  2. Look for the following XML:
    Copy Code
    <!--<Exceptions>
    <add name="VoltageDoesNotMatchSourceException" type="Miner.Geodatabase.Integration.Electric.VoltageDoesNotMatchSourceException, Miner.Geodatabase,Version=9.2.0.0, Culture=neutral, PublicKeyToken=196beceb052ed5dc" Severity="Warning"/>
    <add name="TransformerVoltageInvalidException" type="Miner.Geodatabase.Integration.Electric.TransformerVoltageInvalidException, Miner.Geodatabase,Version=9.2.0.0, Culture=neutral, PublicKeyToken=196beceb052ed5dc" Severity="Error"/>
    <add name="EdgePhasesExceedSourceException" type="Miner.Geodatabase.Integration.Electric.EdgePhasesExceedSourceException, Miner.Geodatabase,Version=9.2.0.0, Culture=neutral, PublicKeyToken=196beceb052ed5dc" Severity="Warning"/>
    <add name="JunctionPhasesDontMatchEdgeException" type="Miner.Geodatabase.Integration.Electric.JunctionPhasesDontMatchEdgeException, Miner.Geodatabase,Version=9.2.0.0, Culture=neutral, PublicKeyToken=196beceb052ed5dc" Severity="Warning"/>
    <add name="FromJunctionNotFoundException" type="Miner.Geodatabase.Integration.Electric.FromJunctionNotFoundException, Miner.Geodatabase,Version=9.2.0.0, Culture=neutral, PublicKeyToken=196beceb052ed5dc" Severity="Error"/>
    <add name="EdgePhasesNothingInCommonException" type="Miner.Geodatabase.Integration.Electric.EdgePhasesNothingInCommonException, Miner.Geodatabase,Version=9.2.0.0, Culture=neutral, PublicKeyToken=196beceb052ed5dc" Severity="Warning"/>
    <add name="EdgeCorruptLineException" type="Miner.Geodatabase.Integration.EdgeCorruptLineException, Miner.Geodatabase,Version=9.2.0.0, Culture=neutral, PublicKeyToken=196beceb052ed5dc" Severity="Warning"/>
    <add name="EdgeMissingToJunctionException" type="Miner.Geodatabase.Integration.Serialization.EdgeMissingToJunctionException, Miner.Geodatabase,Version=9.2.0.0, Culture=neutral, PublicKeyToken=196beceb052ed5dc" Severity="Error"/>
    <add name="EdgeMissingFromJunctionException" type="Miner.Geodatabase.Integration.Serialization.EdgeMissingFromJunctionException, Miner.Geodatabase,Version=9.2.0.0, Culture=neutral, PublicKeyToken=196beceb052ed5dc" Severity="Warning"/>
    <add name="EdgeMissingLineException" type="Miner.Geodatabase.Integration.Serialization.EdgeMissingLineException, Miner.Geodatabase,Version=9.2.0.0, Culture=neutral, PublicKeyToken=196beceb052ed5dc" Severity="Warning"/>
    <add name="JunctionCorruptPointException" type="Miner.Geodatabase.Integration.JunctionCorruptPointException, Miner.Geodatabase,Version=9.2.0.0, Culture=neutral, PublicKeyToken=196beceb052ed5dc" Severity="Error"/>
    <add name="JunctionNotTracedException" type="Miner.Geodatabase.Integration.JunctionNotTracedException, Miner.Geodatabase,Version=9.2.0.0, Culture=neutral, PublicKeyToken=196beceb052ed5dc" Severity="Warning"/> 
    </Exceptions>-->
    
    
    
  3. This section is commented out by default. However, any exception not found in the configuration file (or commented out) is assigned a severity of Warning by default. To change the severity for one or more exceptions, remove the comment marks (highlighted in yellow).
  4. Note at the end of each line is an attribute called "Severity". This attribute determines how Network Adapter reacts when it encounters an error of that type. There are three options:
    • Warning: Network Adapter reports the error and continues with the export. This is the default setting for all exceptions./li>
    • Error: Network Adapter reports the error and ceases the export.
    • Ignore: Network Adapter does not report the error and continues the export.
  5. The list below describes each type of exception available. You may change the Severity attribute for any of these. The default setting for all is Warning.

    Voltage Errors

    • VoltageDoesNotMatchSourceException: An edge's Operating Voltage is not the same as its upstream feature, and it is not immediately downstream of a transformer. Operating Voltage can only change at transformers. Voltage was incorrectly assigned to this feature or its upstream feature, or a transformer is missing.
    • TransformerVoltageInvalidException: To be valid, a transformer's Operating Voltage must match its upstream conductor, and its low-side voltage must match its downstream conductors.

    Phase Errors

    • EdgePhasesExceedSourceException: An edge's phasing exceeds that of its upstream feature. For example, this edge has a phase designation of AB and its upstream feature has A.
    • JunctionPhasesDontMatchEdgeException: A junction feature's phase designation does not match the connected edge(s). For example, the junction's phase designation was ABC and the edge's was A.
    • FromJunctionNotFoundException: The FromJunction was missing for this edge while tracing the feeder for phase consistency.
    • EdgePhasesNothingInCommonException: An edge has no phases in common with its upstream feature. For example, this edge has a phase designation of AB and the upstream feature has C.
    • PhaseFieldDifferentThanOperationalPhasesException: A discrepancy exists between Phase Designation field (i.e., field that has the PhaseDesignation model name assigned) and the operational phasing as interpreted by Feeder Manager. This may happen if phasing on a feature has been manually updated without initializing trace weights.
    • RelatedPhasesExceedOperationalPhasesException: A discrepancy exists between the phasing on the feature and the phasing on its related objects.

    Network Corruption Errors

    • EdgeCorruptLineException: An edge feature's line geometry could not be retrieved.
    • JunctionCorruptPointException: A junction feature's point geometry could not be retrieved.
    • JunctionNotTracedException: The From or To junction of an edge was not found in the trace results. Most likely this is the result of a phase incompatibility between the junction and the edge. For example, the Edge has a phase designation of A and the junction has a phase designation of B.

    Missing Geometry Errors

    • EdgeMissingToJunctionException: An edge was missing its To junction.
    • EdgeMissingFromJunctionException: An edge was missing its From junction.
    • EdgeMissingLineException: An edge was missing its geometry.
  6. When you're finished save and close NetworkAdapter.exe.config.

 

 


Send Comment to ArcFMdocumentation@schneider-electric.com