Version: 10.2.1c and 10.2.1c SP3 |
ArcFM Desktop > ArcFM > Feeder Manager > Which Feeder Manager should I use? > Configure Feeder Manager 1.0 > Feeder Manager Step 12: Configure Default Junctions |
When you build the electric geometric network, a new feature class is created called "ElectricGeometricNetwork"_Junctions. If you want this feature class to participate in Feeder Manager it must be configured.
Field Name
Data Type
FeederID
long integer or string/text (same as CircuitSource)
FeederID2
long integer or string/text
FeederInfo
long integer
ElectricTraceWeight
long integer
ParentCircuitSourceID
long integer
FacilityID
text (length=20)
Field Name
Field Model Name
FeederID
FEEDERID
FeederID2
FEEDERID2
FeederInfo
FEEDERINFO
ElectricTraceWeight
MMELECTRICTRACEWEIGHT
ParentCircuitSourceID
PARENTCIRCUITSOURCEID
FacilityID
FACILITYID
Autoupdaters:
Event
Autoupdater
OnFeatureCreate
ArcFM Create Feeder Object
OnFeatureUpdate
ArcFM Update Feeder Object
If your geometric network was created before you assigned model names and autoupdaters, this step may already have been performed. |