Extended Feeder Manager is configured, like other ArcFM components, by assigning model names and autoupdaters to network features. This step requires that you assign model names and field model names to your feature classes. It is easiest to assign all of the model names and field model names for a feature class rather than assigning all of the model names then all of the field model names.
BusBar:
Field
Field Model Name
Field Info
FacilityID
FACILITYID
Reset After Create = No
Visible = Yes
Editable = YesParentCircuitSourceID*
PARENTCIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoParentCircuitSourceGUID*
PARENTCIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = No*Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.
CircuitSourceID Object Class:
Object Model Name: CIRCUITSOURCEID
Field
Field Model Name
Field Info
GlobalID
CIRCUITSOURCEGLOBALID Reset After Create = Yes
Visible = Yes
Editable = NoCircuitSourceGUID
CIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = NoFeederLevel
FEEDERLEVEL
FeederName
FEEDERNAME
ObjectID
CIRCUITSOURCEID
ParentCircuitSourceID*
PARENTCIRCUITSOURCEID
Reset After Create = Yes
ParentCircuitSourceGUID*
PARENTCIRCUITSOURCEGUID Reset After Create = Yes
RelatedFeatureClassName
RELATEDFEATURECLASSNAME
RelatedObjectID
RELATEDOBJECTID
SubstationID**
SUBSTATIONID
*Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.
**This field is required ONLY for Responder and Network Adapter/DMS implementations. It will not be maintained automatically.
Conductors (primary and secondary):
Field
Field Model Name
Field Info
FacilityID
FACILITYID
Reset After Create = No
Visible = Yes
Editable = YesParentCircuitSourceID*
PARENTCIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoParentCircuitSourceGUID*
PARENTCIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = No*Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.
Delivery Point and Generator:
Field
Field Model Name
Field Info
CircuitSourceGUID°
CIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = NoCircuitSourceGlobalID°
CIRCUITSOURCEGLOBALID Reset After Create = Yes
Visible = Yes
Editable = NoCircuitSourceID°
CIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoFacilityID
FACILITYID
Reset After Create = No
Visible = Yes
Editable = YesParentCircuitSourceGUID*
PARENTCIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = NoParentCircuitSourceID*
PARENTCIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoSubsource
SUBSOURCE
Reset After Create = Yes
Visible = Yes
Editable = Yes*Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.
° Use CircuitSourceID if you plan to use object IDs instead of global IDs. Use CircuitSourceGlobalID and CircuitSourceGUID if you plan to use global IDs instead of object IDs. If you try to assign both object IDs (CircuitSourceGlobalID) and global IDs (CircuitSourceGlobalID and CircuitSourceGUID) to a feature, it will not work with Feeder Manager.
Misc Network Features:
Field
Field Model Name
Field Info
FacilityID
FACILITYID
Reset After Create = No
Visible = Yes
Editable = YesParentCircuitSourceID*
PARENTCIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoParentCircuitSourceGUID*
PARENTCIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = No*Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.
Network Junctions:
Field
Field Model Name
Field Info
FacilityID
FACILITYID
Reset After Create = No
Visible = Yes
Editable = YesParentCircuitSourceID*
PARENTCIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoParentCircuitSourceGUID*
PARENTCIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = No*Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.
Open Point:
Field
Field Model Name
Field Info
CircuitSourceGUID°
CIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = NoCircuitSourceGlobalID°
CIRCUITSOURCEGLOBALID Reset After Create = Yes
Visible = Yes
Editable = NoCircuitSourceID°
CIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoFacilityID
FACILITYID
Reset After Create = No
Visible = Yes
Editable = YesParentCircuitSourceGUID*
PARENTCIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = NoParentCircuitSourceID*
PARENTCIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoSubsource
SUBSOURCE
Reset After Create = Yes
Visible = Yes
Editable = Yes*Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.
° Use CircuitSourceID if you plan to use object IDs instead of global IDs. Use CircuitSourceGlobalID and CircuitSourceGUID if you plan to use global IDs instead of object IDs. If you try to assign both object IDs (CircuitSourceGlobalID) and global IDs (CircuitSourceGlobalID and CircuitSourceGUID) to a feature, it will not work with Feeder Manager.
PF Correcting Equipment:
Field
Field Model Name
Field Info
FacilityID
FACILITYID
Reset After Create = No
Visible = Yes
Editable = YesParentCircuitSourceID*
PARENTCIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoParentCircuitSourceGUID*
PARENTCIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = No*Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.
Primary Meter:
Field
Field Model Name
Field Info
CircuitSourceGUID°
CIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = NoCircuitSourceGlobalID°
CIRCUITSOURCEGLOBALID Reset After Create = Yes
Visible = Yes
Editable = NoCircuitSourceID°
CIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoFacilityID
FACILITYID
Reset After Create = No
Visible = Yes
Editable = YesParentCircuitSourceGUID*
PARENTCIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = NoParentCircuitSourceID*
PARENTCIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoSubsource
SUBSOURCE
Reset After Create = Yes
Visible = Yes
Editable = Yes*Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.
Protective Devices (Dynamic Protective Device and Fuse):
Field
Field Model Name
Field Info
CircuitSourceGUID°
CIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = NoCircuitSourceGlobalID°
CIRCUITSOURCEGLOBALID Reset After Create = Yes
Visible = Yes
Editable = NoCircuitSourceID°
CIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoFacilityID
FACILITYID
Reset After Create = No
Visible = Yes
Editable = YesParentCircuitSourceGUID*
PARENTCIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = NoParentCircuitSourceID*
PARENTCIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoSubsource
SUBSOURCE
Reset After Create = Yes
Visible = Yes
Editable = Yes*Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.
° Use CircuitSourceID if you plan to use object IDs instead of global IDs. Use CircuitSourceGlobalID and CircuitSourceGUID if you plan to use global IDs instead of object IDs. If you try to assign both object IDs (CircuitSourceGlobalID) and global IDs (CircuitSourceGlobalID and CircuitSourceGUID) to a feature, it will not work with Feeder Manager.
Service Point:
Field
Field Model Name
Field Info
FacilityID
FACILITYID
Reset After Create = No
Visible = Yes
Editable = YesParentCircuitSourceID*
PARENTCIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoParentCircuitSourceGUID*
PARENTCIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = No*Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.
Streetlight:
Field
Field Model Name
Field Info
FacilityID
FACILITYID
Reset After Create = No
Visible = Yes
Editable = YesParentCircuitSourceID*
PARENTCIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoParentCircuitSourceGUID*
PARENTCIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = No*Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.
Switch:
Field
Field Model Name
Field Info
CircuitSourceGUID°
CIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = NoCircuitSourceGlobalID°
CIRCUITSOURCEGLOBALID Reset After Create = Yes
Visible = Yes
Editable = NoCircuitSourceID°
CIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoFacilityID
FACILITYID
Reset After Create = No
Visible = Yes
Editable = YesParentCircuitSourceGUID*
PARENTCIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = NoParentCircuitSourceID*
PARENTCIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoSubsource
SUBSOURCE
Reset After Create = Yes
Visible = Yes
Editable = Yes*Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.
° Use CircuitSourceID if you plan to use object IDs instead of global IDs. Use CircuitSourceGlobalID and CircuitSourceGUID if you plan to use global IDs instead of object IDs. If you try to assign both object IDs (CircuitSourceGlobalID) and global IDs (CircuitSourceGlobalID and CircuitSourceGUID) to a feature, it will not work with Feeder Manager.
Transformer:
Field
Field Model Name
Field Info
CircuitSourceGUID°
CIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = NoCircuitSourceGlobalID°
CIRCUITSOURCEGLOBALID Reset After Create = Yes
Visible = Yes
Editable = NoCircuitSourceID°
CIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoFacilityID
FACILITYID
Reset After Create = No
Visible = Yes
Editable = YesParentCircuitSourceGUID*
PARENTCIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = NoParentCircuitSourceID*
PARENTCIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoSubsource
SUBSOURCE
Reset After Create = Yes
Visible = Yes
Editable = Yes*Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.
° Use CircuitSourceID if you plan to use object IDs instead of global IDs. Use CircuitSourceGlobalID and CircuitSourceGUID if you plan to use global IDs instead of object IDs. If you try to assign both object IDs (CircuitSourceGlobalID) and global IDs (CircuitSourceGlobalID and CircuitSourceGUID) to a feature, it will not work with Feeder Manager.
Voltage Regulator:
Field
Field Model Name
Field Info
FacilityID
FACILITYID
Reset After Create = No
Visible = Yes
Editable = YesParentCircuitSourceID*
PARENTCIRCUITSOURCEID
Reset After Create = Yes
Visible = Yes
Editable = NoParentCircuitSourceGUID*
PARENTCIRCUITSOURCEGUID Reset After Create = Yes
Visible = Yes
Editable = No
*Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.