Extended Feeder Manager is configured, like other ArcFM components, by assigning model names and autoupdaters to network features. This step requires that you assign model names and field model names to your feature classes. It is easiest to assign all of the model names and field model names for a feature class rather than assigning all of the model names then all of the field model names.

BusBar:

Field

Field Model Name

Field Info

FacilityID

FACILITYID

Reset After Create = No
Visible = Yes
Editable = Yes

ParentCircuitSourceID*

PARENTCIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

ParentCircuitSourceGUID*

PARENTCIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

  *Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.

 

CircuitSourceID Object Class:

Object Model Name: CIRCUITSOURCEID

 

Field

Field Model Name

Field Info

GlobalID

CIRCUITSOURCEGLOBALID

Reset After Create = Yes
Visible = Yes
Editable = No

CircuitSourceGUID

 

CIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

FeederLevel

FEEDERLEVEL

 

FeederName

FEEDERNAME

 

ObjectID

CIRCUITSOURCEID

 

ParentCircuitSourceID*

PARENTCIRCUITSOURCEID

Reset After Create = Yes

ParentCircuitSourceGUID*

PARENTCIRCUITSOURCEGUID

Reset After Create = Yes

RelatedFeatureClassName

RELATEDFEATURECLASSNAME

 

RelatedObjectID

RELATEDOBJECTID

 

SubstationID**

SUBSTATIONID

  *Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.

**This field is required ONLY for Responder and Network Adapter/DMS implementations. It will not be maintained automatically. 

Conductors (primary and secondary):

Field

Field Model Name

Field Info

FacilityID

FACILITYID

Reset After Create = No
Visible = Yes
Editable = Yes

ParentCircuitSourceID*

PARENTCIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

ParentCircuitSourceGUID*

PARENTCIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

  *Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.

 

Delivery Point and Generator:

Field

Field Model Name

Field Info

CircuitSourceGUID°

CIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

CircuitSourceGlobalID°

CIRCUITSOURCEGLOBALID

Reset After Create = Yes
Visible = Yes
Editable = No

CircuitSourceID°

CIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

FacilityID

FACILITYID

Reset After Create = No
Visible = Yes
Editable = Yes

ParentCircuitSourceGUID*

PARENTCIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

ParentCircuitSourceID*

PARENTCIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

Subsource

SUBSOURCE

Reset After Create = Yes
Visible = Yes
Editable = Yes

  *Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.

 ° Use CircuitSourceID if you plan to use object IDs instead of global IDs. Use CircuitSourceGlobalID and CircuitSourceGUID if you plan to use global IDs instead of object IDs. If you try to assign both object IDs (CircuitSourceGlobalID) and global IDs (CircuitSourceGlobalID and CircuitSourceGUID) to a feature, it will not work with Feeder Manager.

Misc Network Features:

Field

Field Model Name

Field Info

FacilityID

FACILITYID

Reset After Create = No
Visible = Yes
Editable = Yes

ParentCircuitSourceID*

PARENTCIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

ParentCircuitSourceGUID*

PARENTCIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

 *Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.

Network Junctions:

Field

Field Model Name

Field Info

FacilityID

FACILITYID

Reset After Create = No
Visible = Yes
Editable = Yes

ParentCircuitSourceID*

PARENTCIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

ParentCircuitSourceGUID*

PARENTCIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

  *Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.

 

Open Point:

Field

Field Model Name

Field Info

CircuitSourceGUID°

CIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

CircuitSourceGlobalID°

CIRCUITSOURCEGLOBALID

Reset After Create = Yes
Visible = Yes
Editable = No

CircuitSourceID°

CIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

FacilityID

FACILITYID

Reset After Create = No
Visible = Yes
Editable = Yes

ParentCircuitSourceGUID*

PARENTCIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

ParentCircuitSourceID*

PARENTCIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

Subsource

SUBSOURCE

Reset After Create = Yes
Visible = Yes
Editable = Yes

 *Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.

 ° Use CircuitSourceID if you plan to use object IDs instead of global IDs. Use CircuitSourceGlobalID and CircuitSourceGUID if you plan to use global IDs instead of object IDs. If you try to assign both object IDs (CircuitSourceGlobalID) and global IDs (CircuitSourceGlobalID and CircuitSourceGUID) to a feature, it will not work with Feeder Manager.

PF Correcting Equipment:

Field

Field Model Name

Field Info

FacilityID

FACILITYID

Reset After Create = No
Visible = Yes
Editable = Yes

ParentCircuitSourceID*

PARENTCIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

ParentCircuitSourceGUID*

PARENTCIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

  *Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.

Primary Meter:

Field

Field Model Name

Field Info

CircuitSourceGUID°

CIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

CircuitSourceGlobalID°

CIRCUITSOURCEGLOBALID

Reset After Create = Yes
Visible = Yes
Editable = No

CircuitSourceID°

CIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

FacilityID

FACILITYID

Reset After Create = No
Visible = Yes
Editable = Yes

ParentCircuitSourceGUID*

PARENTCIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

ParentCircuitSourceID*

PARENTCIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

Subsource

SUBSOURCE

Reset After Create = Yes
Visible = Yes
Editable = Yes

  *Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.

Protective Devices (Dynamic Protective Device and Fuse):

Field

Field Model Name

Field Info

CircuitSourceGUID°

CIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

CircuitSourceGlobalID°

CIRCUITSOURCEGLOBALID

Reset After Create = Yes
Visible = Yes
Editable = No

CircuitSourceID°

CIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

FacilityID

FACILITYID

Reset After Create = No
Visible = Yes
Editable = Yes

ParentCircuitSourceGUID*

PARENTCIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

ParentCircuitSourceID*

PARENTCIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

Subsource

SUBSOURCE

Reset After Create = Yes
Visible = Yes
Editable = Yes

 *Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.

 ° Use CircuitSourceID if you plan to use object IDs instead of global IDs. Use CircuitSourceGlobalID and CircuitSourceGUID if you plan to use global IDs instead of object IDs. If you try to assign both object IDs (CircuitSourceGlobalID) and global IDs (CircuitSourceGlobalID and CircuitSourceGUID) to a feature, it will not work with Feeder Manager.

Service Point:

Field

Field Model Name

Field Info

FacilityID

FACILITYID

Reset After Create = No
Visible = Yes
Editable = Yes

ParentCircuitSourceID*

PARENTCIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

ParentCircuitSourceGUID*

PARENTCIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

  *Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager. 

Streetlight:

Field

Field Model Name

Field Info

FacilityID

FACILITYID

Reset After Create = No
Visible = Yes
Editable = Yes

ParentCircuitSourceID*

PARENTCIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

ParentCircuitSourceGUID*

PARENTCIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

  *Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.

Switch:

Field

Field Model Name

Field Info

CircuitSourceGUID°

CIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

CircuitSourceGlobalID°

CIRCUITSOURCEGLOBALID

Reset After Create = Yes
Visible = Yes
Editable = No

CircuitSourceID°

CIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

FacilityID

FACILITYID

Reset After Create = No
Visible = Yes
Editable = Yes

ParentCircuitSourceGUID*

PARENTCIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

ParentCircuitSourceID*

PARENTCIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

Subsource

SUBSOURCE

Reset After Create = Yes
Visible = Yes
Editable = Yes

  *Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.

 ° Use CircuitSourceID if you plan to use object IDs instead of global IDs. Use CircuitSourceGlobalID and CircuitSourceGUID if you plan to use global IDs instead of object IDs. If you try to assign both object IDs (CircuitSourceGlobalID) and global IDs (CircuitSourceGlobalID and CircuitSourceGUID) to a feature, it will not work with Feeder Manager.

Transformer:

Field

Field Model Name

Field Info

CircuitSourceGUID°

CIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

CircuitSourceGlobalID°

CIRCUITSOURCEGLOBALID

Reset After Create = Yes
Visible = Yes
Editable = No

CircuitSourceID°

CIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

FacilityID

FACILITYID

Reset After Create = No
Visible = Yes
Editable = Yes

ParentCircuitSourceGUID*

PARENTCIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

ParentCircuitSourceID*

PARENTCIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

Subsource

SUBSOURCE

Reset After Create = Yes
Visible = Yes
Editable = Yes

 *Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.

 ° Use CircuitSourceID if you plan to use object IDs instead of global IDs. Use CircuitSourceGlobalID and CircuitSourceGUID if you plan to use global IDs instead of object IDs. If you try to assign both object IDs (CircuitSourceGlobalID) and global IDs (CircuitSourceGlobalID and CircuitSourceGUID) to a feature, it will not work with Feeder Manager.

Voltage Regulator:

Field

Field Model Name

Field Info

FacilityID

FACILITYID

Reset After Create = No
Visible = Yes
Editable = Yes

ParentCircuitSourceID*

PARENTCIRCUITSOURCEID

Reset After Create = Yes
Visible = Yes
Editable = No

ParentCircuitSourceGUID*

PARENTCIRCUITSOURCEGUID

Reset After Create = Yes
Visible = Yes
Editable = No

   *Use ParentCircuitSourceID if you plan to use object IDs instead of global IDs. Use ParentCircuitSourceGUID if you plan to use global IDs instead of objects IDs. Do not assign both of these fields to the same feature or the feature will not work with Feeder Manager.

 

 


Send Comment to ArcFMdocumentation@schneider-electric.com