Version: 10.2.1c and 10.2.1c SP3 |
ArcFM Desktop > Conduit Manager > Phase Designation > Configure Phase Designation |
To configure Phase Designation for use in your geodatabase, follow these steps:
DUCTID
PHASEDESIGNATIONCM or PHASEDESIGNATION
ULSTEXTFIELD
These domains contain the coded values that represent the phase or phase combinations of conductors. If you list a Phase with multiple characters (e.g., AB), then each individual character must be represented in the domain as well (e.g., A, B). Listing a multi-character value (ABC) without entering rows for each individual character (A, B, C) will cause errors. |
Phase |
Coded Value |
---|---|
C |
1 |
B |
2 |
BC |
3 |
A |
4 |
AC |
5 |
AB |
6 |
ABC |
7 |
Field Name |
Data Type |
Domain |
---|---|---|
PhaseDesignation |
long integer |
Phase Designation |
Field Name |
Data Type |
---|---|
DuctID |
text |
Conductor (Cable) feature classes
Note: Conduit Manager looks first for the PHASEDESIGNATIONCM field model name. If it isn't found, it looks for the PHASEDESIGNATION field model name.
Duct Definition object class