ArcFM Solution Configuration Guide
Troubleshooting: An autoupdater appears to be missing from the dropdown menu

Version: 10.2.1c and 10.2.1.c SP3

Resource Center Home

Autoupdaters appear as available for attributes based on the field's data type and optionally the domain assigned to the field.

The autoupdaters that appear as available for an attribute are filtered by the data type of the field. For example, the 'Length Integer' autoupdater for the Measured Length field will not be available if the measured length field is anything other than Long Integer.

If you have a domain assigned to a field, an autoupdater must have that domain name specified in the code or it will not appear as an available autoupdater for that field. For example, if you have a domain called "phase_designation" assigned to the Phase Designation field and the ArcFM Auto Phase Assign autoupdater isn't in the list, it is because the autoupdater is looking for a domain by a different name or not at all. The "phase_designation" domain isn't specified in the code.

If an autoupdater has a domain specified in the code and it isn't assigned to that field, the autoupdater will not appear in the dropdown. If there was no domain assigned to the Phase Designation field, the ArcFM Auto Phase Assign AU would not show up in the list because it requires the Phase Designation domain.

 

 


Send Comment to ArcFMdocumentation@schneider-electric.com