ArcFM Solution Configuration Guide
SqueezeOff

Version: 10.2.1c and 10.2.1.c SP3

Resource Center Home

A SqueezeOff represents a section of pinched pipe.

Gas tracing requires the SQUEEZEOFF class model name and is used to determine whether pinching the pipes at selected locations will isolate an area.  

Subtypes: None

Associations: Meter

Model Names: SQUEEZEOFF

Attributes:

Comments: text - User or designer comments.

GasTraceWeight: long integer - Information used for tracing analysis; stored in a bitgate.

Hyperlink: text - Used to store a hyperlink path via standard Esri hyperlinking functionality.

NormalPosition: long integer - Normal position of GasValve; domain values include Open and Closed.

SymbolRotation: double - Angle that dictates how the feature appears on a map.

Subtype: long integer - Code indicating type of GasDevice, examples include Gas Lamp, Relief Valve, and Gas Station.

 

 