ArcFM Solution Configuration Guide
PipeExposure

Version: 10.2.1c and 10.2.1.c SP3

Resource Center Home

PipeExposure refers to a section of gas pipe that has been exposed.

Subtypes: None

Associations: GasPipe, ExposedPipeInspection

Model Names: None

Attributes:

Comments: text - User and designer comments.

CorrosionCode: text - Code indicating degree of corrosion; domain values include None, Light, Moderate, and Heavy.

CorrosionExtent: text - Code indicating extent of corrosion; domain values include General and Localized.

DistributionMainObjectID: long integer - ObjectID of associated Distribution Main.

Hyperlink: text -Used to store a hyperlink path via standard Esri hyperlinking functionality.

InspectionDate: date - Date of last inspection.

InstallationDate: date - Date of installation.

LengthExposed: text - Length of pipe that is exposed.

LocationDescription: text - Verbal description of location of exposed pipe.

ServiceObjectID: long integer - ObjectID of associated Service.

 

 