InductionMotor is an electric transformer with a magnetic circuit separated by an air gap into two movable portions carrying the primary and secondary windings. Secondary currents are created by induction rather than being supplied by a dc exciter or other external power source. Types of induction motor are wound rotor and squirrel cage.
Induction motors have National Electric Manufacturers Association (NEMA) specifications.
Associations: ServicePoint
Subtypes: None
Model Names: None
Attributes:
ConnectionConfiguration: text - Code indicating connection configuration of InductionMotor; domain values include Delta and Wye.
Efficiency: double - Efficiency, expressed in percentage.
GroundReactance: double - Ground reactance of InductionMotor in ohms.
GroundResistance: double - Ground resistance of InductionMotor in ohms.
Hyperlink: text - Used to store a hyperlink path via standard Esri hyperlinking functionality.
LockedRotorMultiplier: double - Higher current required to start motor in percentage.
LockedRotorPF: double - Power factor of locked rotor, expressed as less than one or as percentage.
MotorStartLimit: double - Motor start limit.
MotorStartLimitAmount: double - Motor start limit amount.
NEMALockedRotorRatio: double - NEMA locked rotor kVA/HP ratio.
NominalVoltage: long integer - Standard level of normal ratings for system voltage, expressed as line to line or line to neutral; domain values include 4.16 kV Grounded Y, 7.2 kV Grounded Y, etc.
PhaseDesignation: long integer - Code indicating phases present; domain values include A, AB, AC, etc.
PowerFactor: double - Power factor expressed as less than one or as percentage.
RatedHP: double - Rated horsepower.
ServicePointObjectID: long integer - ObjectID of ServicePoint.
SoftStartReactance: double - Soft start reactance, X.
SoftStartResistance: double - Soft start resistance, R.
SoftStartTap: double - Soft start tap.
SoftStartWinding: double - Soft start winding.