ArcFM Solution Configuration Guide
Gas Pressure System

Version: 10.2.1c and 10.2.1.c SP3

Resource Center Home

The purpose of this trace is to find connected features of equal operating pressures with two types of regulators acting as barriers: either all regulators or regulators with different inlet and outlet pressures. For the All Regulators option, the solver only looks at regulators for junctions that have Bit 20 (Regulator) set. It sets these features as the barriers to the trace and performs the trace, disregarding the Bit 17 (Gas Pressure System Boundary) setting. For the Regulators with different inlet and outlet pressures option, the solver looks for junctions with both Bit 20 and Bit 17 set. This option allows you to stop the pressure system trace at features other than regulators. For valves, the solver looks at only Bit 17.

The results include all of the features reached from the flag except for the Regulators that were barriers for the trace. Regulators placed along a complex edge will not interrupt the selection of the entire complex edge. The Drawing option for returning results allows you to draw only individual segments of the complex edge.

 

Object Class Model Names: Regulator

Field Name (can be any name)

Field Model Name (exact spelling)

Gas Pressure System Status

GASPRESSURESYSTEMSTATUS

Normal Position

NORMALPOSITION

SOP In

SOPIN (optional)

SOP Out

SOPOUT (optional)

 

Pressure System Bit Interpretations

 

 

 


Send Comment to ArcFMdocumentation@schneider-electric.com