ArcFM Solution Configuration Guide
GasMeter

Version: 10.2.1c and 10.2.1.c SP3

Resource Center Home

Accurate measurement of volume of gas flowing in pipelines is crucial to well analysis and loss prevention. Meter types include diaphragm, orifice, and rotary.

Subtypes: None

Associations: MeterSetting, RuralTap, TownBorderStation

Model Names: None

Attributes:

Comments: text - User or designer comments.

Hyperlink: text - Used to store a hyperlink path via standard Esri hyperlinking functionality.

FlowCapacity: text -Rated capacity in cubic feet per minute (cfm).

MeterMAOP: double -Maximum allowable operating pressure of meter.

MeterSettingObjectID: long integer -ObjectID of associated MeterSetting.

MeterType: text -Code indicating meter type; domain values include Diaphragm, Orifice, and Rotary.

Owner: text -Owner of Meter.

PressureRating: text -Pressure across meter in psi.

PropertyUnitCode: text -Value assigned to assets to track and classify Property Records.

RecordingMethod: text -Time recording method to calculate volume.

RuralTapObjectID: long integer -ObjectID of associated RuralTap.

SerialNumber: text -Serial number of meter.

TBSObjectID: long integer -Object ID of associated town border station.

 

 


Send Comment to ArcFMdocumentation@schneider-electric.com