CustomerConnection contains information about the service provided to the customer.

Associations: ServiceAddress

Subtypes: None

Model Names: None

Attributes:

Address: text - Customer address.

Alternate[X,Y,Z]: double - Stores the X, Y, and Z values from a GPS device.

AlternateSource: text - This field contains a value from the Feature Source domain that indicates an alternate source for the structure.

ConnectionType: text - Type of connection.

PhaseDesignation: long integer - Code indicating phases present; domain values include A, AB, AC, etc. Feeder Manager requires the PHASEDESIGNATION model name on this field for both ServicePoints and PrimaryMeters.

ServiceCurrentRating: short integer - Code indicating maximum rating of service delivered to CustomerConnection; domain values include 100 amps, 600 amps, etc.

 

International Data Model

In addition to the attributes listed above, the following attribute is used by the international electric data model.

CIS_ID - ID of customer as known to a Customer Information System (CIS).

 

 