Version: 10.2.1c and 10.2.1.c SP3 |
Appendix > Electric Distribution Data Model > Customer and Service Overview > Customer Connection |
CustomerConnection contains information about the service provided to the customer.
Associations: ServiceAddress
Subtypes: None
Model Names: None
Attributes:
Address: text - Customer address.
Alternate[X,Y,Z]: double - Stores the X, Y, and Z values from a GPS device.
AlternateSource: text - This field contains a value from the Feature Source domain that indicates an alternate source for the structure.
ConnectionType: text - Type of connection.
PhaseDesignation: long integer - Code indicating phases present; domain values include A, AB, AC, etc. Feeder Manager requires the PHASEDESIGNATION model name on this field for both ServicePoints and PrimaryMeters.
ServiceCurrentRating: short integer - Code indicating maximum rating of service delivered to CustomerConnection; domain values include 100 amps, 600 amps, etc.
International Data Model
In addition to the attributes listed above, the following attribute is used by the international electric data model.
CIS_ID - ID of customer as known to a Customer Information System (CIS).