ArcFM Desktop > ArcFM > Gas Tracing > Create Domains |
There are several domains that may be created to work with Gas Tracing. These domains provide the coded values for various functionality within Gas Tracing. Below are the domains that are provided with the ArcFM Solution sample data. Except for the Material Conductivity domain, you may name the domains as you like and modify the Description values as needed. Do not alter Code values.
CPSystemStatus
CPSystemStatus domain properties:
- Field Type = long integer
- Domain Type = Coded Values
- Split Policy = Duplicate
- Merge Policy = Default Value
CPSystemStatus domain coded values:
Code
Description
0
Closed
1
Open
Gas Pipe Diameter
Gas Pipe Diameter domain properties:
- Field Type = Text
- Domain Type = Coded Values
- Split Policy = Duplicate
- Merge Policy = Default Value
Gas Pipe Diameter domain coded values:
This domain shows a partial listing of the values in the ArcFM sample data Gas Pipe Diameter domain. See the sample data for all domain values.
Code
Description
0.25
1/4"
0.38
3/8"
0.5
1/2"
0.63
5/8"
0.75
3/4"
0.88
7/8"
1
1"
UNK
Unknown
While the following two domains have similar names, they have different field types. When assigning domains to fields, the domains are filtered by field type. So you will never see a domain with a field type of text while viewing a field with a field type of long integer. |
GasWaterSystemStatus - String
GasWaterSystemStatus - String domain properties:
- Field Type = text
- Domain Type = Coded Values
- Split Policy = Duplicate
- Merge Policy = Default Value
GasWaterSystemStatus - String domain coded values:
Code
Description
N
Not a Boundary
Y
Boundary
GasWaterSystemStatus - Integer
GasWaterSystemStatus - Integer domain properties:
- Field Type = long integer
- Domain Type = Coded Values
- Split Policy = Duplicate
- Merge Policy = Default Value
GasWaterSystemStatus - Integer domain coded values:
Code
Description
0
Not a Boundary
1
Boundary
Material Domain
Material domain properties:
- Field Type = text
- Domain Type = Coded Values
- Split Policy = Duplicate
- Merge Policy = Default Value
Material domain coded values:
Code
Description
CI
Cast Iron
MTL
Metal
PL
Plastic
ST
Steel
UNK
Unknown
Note for GasTraceWeight Autoupdaters: In addition to other factors, material type determines conductivity for cathodic protection purposes. Review the Material Conductivity Domain section in the Configure Domains for Cathodic Protection topic for guidance in adding material types or subtypes to your geodatabase.
You can also create a numeric Material domain:
Material domain properties:
- Field Type = long integer
- Domain Type = Coded Values
- Split Policy = Duplicate
- Merge Policy = Default Value
Material domain coded values:
Code
Description
1
Copper
2
Cast Iron
3
Steel
4
Metal
5
Plastic
Material Conductivity
Material Conductivity domain properties:
- Field Type = text
- Domain Type = Coded Values
- Split Policy = Default Value
- Merge Policy = Default Value
GasConductivity domain coded values: These coded values determine whether particular material types are conductive. Review the Material Conductivity Domain section in the Configure Domains for Cathodic Protection topic for guidance.
Normal Position Domain
Normal Position domain properties:
- Field Type = long integer
- Domain Type = Coded Values
- Split Policy = Duplicate
- Merge Policy = Default Value
Normal Position domain coded values:
Code
Description
0
Closed
1
Open
Operating Classification Domain
Operating Classification domain properties:
- Field Type = text
- Domain Type = Coded Values
- Split Policy = Duplicate
- Merge Policy = Default Value
Operating Classification domain coded values:
Code
Description
CIR
Critical/Inspection Required
CINR
Critical/Inspection Not Required
NC
Non-Critical
Pipe Type Domain
Pipe Type domain properties:
- Field Type = text
- Domain Type = Coded Values
- Split Policy = Duplicate
- Merge Policy = Default Value
Pipe Type domain coded values:
Code
Description
P
Pinchable
NP
Non-Pinchable
Station Status Domain
Station Status Indicator domain properties:
- Field Type = text
- Domain Type = Coded Values
- Split Policy = Duplicate
- Merge Policy = Default Value
Station Status Indicator domain coded values:
Code
Description
OFF
Offline
ONL
Online
UNK
Unknown
Surface Area Conversion Factor Domain
Station Status Indicator domain properties:
- Field Type = text
- Domain Type = Coded Values
- Split Policy = Default Value
- Merge Policy = Default Value
Surface Area Conversion Factor domain coded values:
Code
Description
FACTOR
0.0833333333
Yes/No Indicator Domain
Yes/No Indicator domain properties:
- Field Type = text
- Domain Type = Coded Values
- Split Policy = Duplicate
- Merge Policy = Default Value
Yes/No Indicator domain coded values:
Code
Description
Y
Yes
N
No