This step requires that you assign autoupdaters to your feature classes. Autoupdaters are assigned using the Object Info tab of the ArcFM Properties Manager. Autoupdaters must be assigned in the order shown (combo AUs cannot be used in place of those shown).

BusBar:

Event

Autoupdater

On Feature Create

Remove the ArcFM Create Feeder Object AU and assign these:
1. ArcFM Generic Electric Trace Weight
2. ArcFM FeederSubSource Level
3. ArcFM Internal FeederID Create

On Feature Update

Remove the ArcFM Update Feeder Object AU and assign these:
1. ArcFM Generic Electric Trace Weight
2. ArcFM FeederSubSource Level
3. ArcFM Internal FeederID Update

On Feature Delete ArcFM Delete Feeder Object

 

CircuitSourceID:

Event

Autoupdater

On Feature Update

ArcFM Internal FeederID Update

 

Conductors (primary and secondary):

Event

Autoupdater

On Feature Create

If you never want to use this feature as a subsource, use the Create Feeder Object AU.

If you do want this feature to be a subsource, remove the ArcFM Create Feeder Object AU and assign these:
1. ArcFM Generic Electric Trace Weight
2. ArcFM FeederSubSource Level
3. ArcFM Internal FeederID Create

On Feature Update

If you never want to use this feature as a subsource, use the Update Feeder Object AU.

If you do want this feature to be a subsource, remove the ArcFM Update Feeder Object AU and assign these:

1. ArcFM Generic Electric Trace Weight
2. ArcFM FeederSubSource Level
3. ArcFM Internal FeederID Update

On Feature Delete

ArcFM OH - Delete Feeder Conductor/Units or ArcFM UG - Delete Feeder Conductor/Units

 

Delivery Point and Generator:

Event

Autoupdater

On Feature Create

If you never want to use this feature as a subsource, use the Create Feeder Object AU.

Certain AUs are not available if you configure EFM using GUIDs. Instead, assign the CircuitSourceID model name, which allows you to assign the desired AUs.
Then unassign the CircuitSourceID model name. The AUs will persist.

If you do want this feature to be a subsource, remove the ArcFM Create Feeder Object AU and assign these:

1. ArcFM Generic Electric Trace Weight
2. ArcFM Feeder SubSource Relator
3. ArcFM Feeder SubSource Name
4. ArcFM FeederSubSource Level
5. ArcFM Internal FeederID Create

On Feature Update

If you never want to use this feature as a subsource, use the Update Feeder Object AU.

Certain AUs are not available if you configure EFM using GUIDs. Instead, assign the CircuitSourceID model name, which allows you to assign the desired AUs.
Then unassign the CircuitSourceID model name. The AUs will persist.

If you do want this feature to be a subsource, remove the ArcFM Update Feeder Object AU and assign these:

1. ArcFM Generic Electric Trace Weight
2. ArcFM Feeder SubSource Relator
3. ArcFM Feeder SubSource Name
4. ArcFM FeederSubSource Level
5. ArcFM Internal FeederID Update

 

Open Point:

Event

Autoupdater

On Feature Create

If you never want to use this feature as a subsource, use the Create Feeder Object AU.

Certain AUs are not available if you configure EFM using GUIDs. Instead, assign the CircuitSourceID model name, which allows you to assign the desired AUs.
Then unassign the CircuitSourceID model name. The AUs will persist.

If you do want this feature to be a subsource, remove the ArcFM Create Feeder Object AU and assign these:

1. ArcFM Generic Electric Trace Weight
2. ArcFM Feeder SubSource Relator
3. ArcFM Feeder SubSource Name
4. ArcFM FeederSubSource Level
5. ArcFM Internal FeederID Create

On Feature Update

If you never want to use this feature as a subsource, use the Update Feeder Object AU.

Certain AUs are not available if you configure EFM using GUIDs. Instead, assign the CircuitSourceID model name, which allows you to assign the desired AUs.
Then unassign the CircuitSourceID model name. The AUs will persist.

If you do want this feature to be a subsource, remove the ArcFM Update Feeder Object AU and assign these:

1. ArcFM Generic Electric Trace Weight
2. ArcFM Feeder SubSource Relator
3. ArcFM Feeder SubSource Name
4. ArcFM FeederSubSource Level
5. ArcFM Internal FeederID Update

On Feature Delete ArcFM Delete Feeder Object

 

Primary Meter:

Event

Autoupdater

On Feature Create

If you never want to use this feature as a subsource, use the Create Feeder Object AU.

Certain AUs are not available if you configure EFM using GUIDs. Instead, assign the CircuitSourceID model name, which allows you to assign the desired AUs.
Then unassign the CircuitSourceID model name. The AUs will persist.

If you do want this feature to be a subsource, remove the ArcFM Create Feeder Object AU and assign these:

1. ArcFM Generic Electric Trace Weight
2. ArcFM Feeder SubSource Relator
3. ArcFM Feeder SubSource Name
4. ArcFM FeederSubSource Level
5. ArcFM Internal FeederID Create

On Feature Update

If you never want to use this feature as a subsource, use the Update Feeder Object AU.

Certain AUs are not available if you configure EFM using GUIDs. Instead, assign the CircuitSourceID model name, which allows you to assign the desired AUs.
Then unassign the CircuitSourceID model name. The AUs will persist.

If you do want this feature to be a subsource, remove the ArcFM Update Feeder Object AU and assign these:

1. ArcFM Generic Electric Trace Weight
2. ArcFM Feeder SubSource Relator
3. ArcFM Feeder SubSource Name
4. ArcFM FeederSubSource Level
5. ArcFM Internal FeederID Update

 

Protective Devices (Dynamic Protective Device and Fuse):

Event

Autoupdater

On Feature Create

If you never want to use this feature as a subsource, use the Create Feeder Object AU.

Certain AUs are not available if you configure EFM using GUIDs. Instead, assign the CircuitSourceID model name, which allows you to assign the desired AUs.
Then unassign the CircuitSourceID model name. The AUs will persist.

If you do want this feature to be a subsource, remove the ArcFM Create Feeder Object AU and assign these:

1. ArcFM Generic Electric Trace Weight
2. ArcFM Feeder SubSource Relator
3. ArcFM Feeder SubSource Name
4. ArcFM FeederSubSource Level
5. ArcFM Internal FeederID Create

On Feature Update

If you never want to use this feature as a subsource, use the Update Feeder Object AU.

Certain AUs are not available if you configure EFM using GUIDs. Instead, assign the CircuitSourceID model name, which allows you to assign the desired AUs.
Then unassign the CircuitSourceID model name. The AUs will persist.

If you do want this feature to be a subsource, remove the ArcFM Update Feeder Object AU and assign these:

1. ArcFM Generic Electric Trace Weight
2. ArcFM Feeder SubSource Relator
3. ArcFM Feeder SubSource Name
4. ArcFM FeederSubSource Level
5. ArcFM Internal FeederID Update

On Feature Delete ArcFM Delete Feeder Object

 

Switch:

Event

Autoupdater

On Feature Create

If you never want to use this feature as a subsource, use the Create Feeder Object AU.

Certain AUs are not available if you configure EFM using GUIDs. Instead, assign the CircuitSourceID model name, which allows you to assign the desired AUs.
Then unassign the CircuitSourceID model name. The AUs will persist.

If you do want this feature to be a subsource, remove the ArcFM Create Feeder Object AU and assign these:
1. ArcFM Generic Electric Trace Weight
2. ArcFM Feeder SubSource Relator
3. ArcFM Feeder SubSource Name
4. ArcFM FeederSubSource Level
5. ArcFM Internal FeederID Create

On Feature Update

If you never want to use this feature as a subsource, use the Update Feeder Object AU.

Certain AUs are not available if you configure EFM using GUIDs. Instead, assign the CircuitSourceID model name, which allows you to assign the desired AUs.
Then unassign the CircuitSourceID model name. The AUs will persist.

If you do want this feature to be a subsource, remove the ArcFM Update Feeder Object AU and assign these:

1. ArcFM Generic Electric Trace Weight
2. ArcFM Feeder SubSource Relator
3. ArcFM Feeder SubSource Name
4. ArcFM FeederSubSource Level
5. ArcFM Internal FeederID Update

On Feature Delete ArcFM Delete Feeder Object

 

Transformer:

Event

Autoupdater

On Feature Create

If you never want to use this feature as a subsource, use the Create Feeder Object AU.

Certain AUs are not available if you configure EFM using GUIDs. Instead, assign the CircuitSourceID model name, which allows you to assign the desired AUs.
Then unassign the CircuitSourceID model name. The AUs will persist.

If you do want this feature to be a subsource, remove the ArcFM Create Feeder Object AU and assign these:

1. ArcFM Generic Electric Trace Weight
2. ArcFM Feeder SubSource Relator
3. ArcFM Feeder SubSource Name
4. ArcFM FeederSubSource Level
5. ArcFM Internal FeederID Create

On Feature Update

If you never want to use this feature as a subsource, use the Update Feeder Object AU.

Certain AUs are not available if you configure EFM using GUIDs. Instead, assign the CircuitSourceID model name, which allows you to assign the desired AUs.
Then unassign the CircuitSourceID model name. The AUs will persist.

If you do want this feature to be a subsource, remove the ArcFM Update Feeder Object AU and assign these:

1. ArcFM Generic Electric Trace Weight
2. ArcFM Feeder SubSource Relator
3. ArcFM Feeder SubSource Name
4. ArcFM FeederSubSource Level
5. ArcFM Internal FeederID Update

On Feature Delete ArcFM Delete Feeder Object

 

 

 


Send Comment to ArcFMdocumentation@schneider-electric.com