ArcFM Desktop > ArcFM > Feeder Manager > Upgrade to Extended Feeder Manager > EFM: Add Fields |
Add the fields to the following feature classes. The ParentCircuitSourceID or ParentCircuitSourceGUID field (but not both) must be added to ALL features that participate in the electric geometric network. The CircuitSourceID (or CircuitSourceGlobalID and CircuitSourceGUID fields) and SubSource fields must be added to any feature classes that may be designated as subsources and/or ultimate sources. This page provides examples. You may wish to use different features as subsources and ultimate sources.
BusBar:
Field
Data Type
Domain
ParentCircuitSourceGUID
GUID
No domain
Default value = nullAdd either ParentCircuitSourceGUID or ParentCircuitSourceID, but not both. If both are added the feature will not work with the manager. ParentCircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullFacilityID
text (length=20)
No domain
Default value = null
Conductors (primary and secondary):
Field
Data Type
Domain
ParentCircuitSourceGUID
GUID
No domain
Default value = nullAdd either ParentCircuitSourceGUID or ParentCircuitSourceID, but not both. If both are added the feature will not work with the manager. ParentCircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullFacilityID
text (length=20)
No domain
Default value = null
Delivery Point and Generator:
Field
Data Type
Domain
CircuitSourceGlobalID
Global ID
No domain
Default value = nullCircuitSourceGUID
GUID
No domain
Default value = nullAdd either only CircuitSourceID or CircuitSourceGUID, but not both. If both are added, the feature will not work with the manager.
CircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullFacilityID
text (length=20)
No domain
Default value = nullParentCircuitSourceGUID
GUID
No domain
Default value = nullAdd either ParentCircuitSourceGUID or ParentCircuitSourceID, but not both. If both are added, the feature will not work with the manager.
ParentCircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullSubSource
short integer
Yes/No domain
Data type = 16-bit integer
Default value = null
Misc Network Features:
Field
Data Type
Domain
ParentCircuitSourceGUID
GUID
No domain
Default value = nullAdd either ParentCircuitSourceGUID or ParentCircuitSourceID, but not both. If both are added, the feature will not work with the manager. ParentCircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullFacilityID
text (length=20)
No domain
Default value = null
Network Junctions:
Field
Data Type
Domain
ParentCircuitSourceGUID
GUID
No domain
Default value = nullAdd either ParentCircuitSourceGUID or ParentCircuitSourceID, but not both. If both are added, the feature will not work with the manager. ParentCircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullFacilityID
text (length=20)
No domain
Default value = null
Open Point:
Field
Data Type
Domain
CircuitSourceGlobalID
Global ID
No domain
Default value = nullCircuitSourceGUID
GUID
No domain
Default value = nullAdd either only CircuitSourceID or CircuitSourceGUID, but not both. If both are added, the feature will not work with the manager.
CircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullFacilityID
text (length=20)
No domain
Default value = nullParentCircuitSourceGUID
GUID
No domain
Default value = nullAdd either ParentCircuitSourceGUID or ParentCircuitSourceID, but not both. If both are added, the feature will not work with the manager.
ParentCircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullSubSource
short integer
Yes/No domain
Data type = 16-bit integer
Default value = null
PF Correcting Equipment:
Field
Data Type
Domain
ParentCircuitSourceGUID
GUID
No domain
Default value = nullAdd either ParentCircuitSourceGUID or ParentCircuitSourceID, but not both. If both are added, the feature will not work with the manager. ParentCircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullFacilityID
text (length=20)
No domain
Default value = null
Primary Meter:
Field
Data Type
Domain
CircuitSourceGlobalID
Global ID
No domain
Default value = nullCircuitSourceGUID
GUID
No domain
Default value = nullAdd either only CircuitSourceID or CircuitSourceGUID, but not both. If both are added, the feature will not work with the manager.
CircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullFacilityID
text (length=20)
No domain
Default value = nullParentCircuitSourceGUID
GUID
No domain
Default value = nullAdd either ParentCircuitSourceGUID or ParentCircuitSourceID, but not both. If both are added, the feature will not work with the manager.
ParentCircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullSubSource
short integer
Yes/No domain
Data type = 16-bit integer
Default value = null
Protective Devices (Dynamic Protective Device and Fuse):
Field
Data Type
Domain
CircuitSourceGlobalID
Global ID
No domain
Default value = nullCircuitSourceGUID
GUID
No domain
Default value = nullAdd either only CircuitSourceID or CircuitSourceGUID, but not both. If both are added, the feature will not work with the manager.
CircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullFacilityID
text (length=20)
No domain
Default value = nullParentCircuitSourceGUID
GUID
No domain
Default value = nullAdd either ParentCircuitSourceGUID or ParentCircuitSourceID, but not both. If both are added, the feature will not work with the manager.
ParentCircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullSubSource
short integer
Yes/No domain
Data type = 16-bit integer
Default value = null
Service Point:
Field
Data Type
Domain
ParentCircuitSourceGUID
GUID
No domain
Default value = nullAdd either ParentCircuitSourceGUID or ParentCircuitSourceID, but not both. If both are added, the feature will not work with the manager. ParentCircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullFacilityID
text (length=20)
No domain
Default value = null
Streetlight:
Field
Data Type
Domain
ParentCircuitSourceGUID
GUID
No domain
Default value = nullAdd either ParentCircuitSourceGUID or ParentCircuitSourceID, but not both. If both are added, the feature will not work with the manager. ParentCircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullFacilityID
text (length=20)
No domain
Default value = null
Switch:
Field
Data Type
Domain
CircuitSourceGlobalID
Global ID
No domain
Default value = nullCircuitSourceGUID
GUID
No domain
Default value = nullAdd either only CircuitSourceID or CircuitSourceGUID, but not both. If both are added, the feature will not work with the manager.
CircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullFacilityID
text (length=20)
No domain
Default value = nullParentCircuitSourceGUID
GUID
No domain
Default value = nullAdd either ParentCircuitSourceGUID or ParentCircuitSourceID, but not both. If both are added, the feature will not work with the manager.
ParentCircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullSubSource
short integer
Yes/No domain
Data type = 16-bit integer
Default value = null
Transformer:
Field
Data Type
Domain
CircuitSourceGlobalID
Global ID
No domain
Default value = nullCircuitSourceGUID
GUID
No domain
Default value = nullAdd either only CircuitSourceID or CircuitSourceGUID, but not both. If both are added, the feature will not work with the manager.
CircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullFacilityID
text (length=20)
No domain
Default value = nullParentCircuitSourceGUID
GUID
No domain
Default value = nullAdd either ParentCircuitSourceGUID or ParentCircuitSourceID, but not both. If both are added, the feature will not work with the manager.
ParentCircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullSubSource
short integer
Yes/No domain
Data type = 16-bit integer
Default value = null
Voltage Regulator:
Field
Data Type
Domain
ParentCircuitSourceGUID
GUID
No domain
Default value = nullAdd either ParentCircuitSourceGUID or ParentCircuitSourceID, but not both. If both are added the feature will not work with Feeder Manager. ParentCircuitSourceID
long integer
No domain
Data type = 32-bit integer
Default value = nullFacilityID
text (length=20)
No domain
Default value = null