ArcFM Desktop Configuration Guide
Add to Fiber Circuits

Resource Center Home

A circuit is defined as a path of glass that carries one or more wavelengths of light along the path. Circuit Manager allows you to manage circuit information by creating and editing circuits associated with an end-to-end path in the fiber network. Most commonly, connectable objects participate in the Circuit Manager.

This topic describes the settings needed for a feature participating in the Circuit Manager.  It includes a table that shows the settings used by all features participating in the Circuit Manager.

Tips for Using this Table

  • The Example Field and Data Type columns contain values entered when the feature is created. If using the worksheet, record these values in Table 5.
  • The Field Model Name column contains values entered in the ArcFM Properties Manager on the Field Model Names tab. If using the worksheet, record these values in Table 5.
  • The Class Model Name column contains values entered in the ArcFM Properties Manager on the Model Names tab. If using the worksheet, record these values in Table 4.

 

Example Field Name

Data Type

Field Model Name

Class Model Name

FiberCircuitGlobalID

GUID

FIBERCIRCUITGLOBALID

FIBERCIRCUITPARTICIPANT

  

Required Relationship:

In order to participate in the Circuit Manager, the feature must also have a relationship to the Circuit object class (e.g., F_Circuit). This relationship must be a simple, one-to-many, non-attributed relationship from the Circuit table to the feature based on the "GlobalID" field of the Circuit and the "FiberCircuitGlobalID" field of the feature. Enter this information in Table 2 of the worksheet.

 

 

 