Appendix > Autoupdaters > Feeder Manager Autoupdaters |
Version: 10.1 |
Feeder Manager autoupdaters are special autoupdaters that support Feeder Manager functionality. To initialize several tasks concurrently, some autoupdaters are combined.
Component |
Description |
Used by Feature Classes |
Visible? |
Product Compatibility |
---|---|---|---|---|
ArcFM Create Feeder Object |
Combo = Generic Electric Trace Weight + Internal FeederID Create |
BusBar, DynamicProtectiveDevice, Fuse, Switch, OpenPoint, Transformer, PrimaryMeter, UGElectricLineSegment, OHElectricLineSegment |
Yes |
Desktop Server |
ArcFM Delete Feeder Object |
Maintains FeederID in response to a delete event |
|
Yes |
Desktop Server |
ArcFM Generic Electric Trace Weight |
Updates the trace weight field for a database. It relies on model names rather than a specific data model |
|
Yes |
Desktop Server |
ArcFM Internal FeederID Create |
Maintains FeederID in response to a create event |
|
No |
Desktop Server |
ArcFM Internal FeederID Update |
Maintains Feeder ID in response to an update event |
|
No |
Desktop Server |
ArcFM OH — Delete Feeder Conductor/Units |
Combo = Delete Feeder Object + Remove Conductor Units |
OHElectricLineSegment |
Yes |
Desktop Server |
ArcFM Relate / Create Feeder Object |
Combo = Structure Relate + Create Feeder Object |
|
Yes |
Desktop Server |
ArcFM Relate / Update Feeder Object |
Combo = Structure Relate + Update Feeder Object |
|
Yes |
Desktop Server |
ArcFM Split / Relate / Create Feeder Object |
Combo = Segment Split + Structure Relate + Create Feeder Object |
|
Yes |
Desktop Server |
ArcFM Split Feeder Object |
Maintains FeederID in response to a split event |
UGElectricLineSegment, OHElectricLineSegment |
Yes |
Desktop Server |
ArcFM UG Delete Feeder Conductor/Units |
Combo = Delete Feeder Object + Remove Deleted ULSMember + Remove Conductor Units |
BusBar, DynamicProtectiveDevice, Fuse, Switch, OpenPoint, Transformer, PrimaryMeter, UGElectricLineSegment, OHElectricLineSegment |
Yes |
Desktop Server |
ArcFM Update Feeder Object |
Combo = Generic Electric Trace Weight + Internal FeederID Update |
BusBar, DynamicProtectiveDevice, Fuse, Switch, OpenPoint, Transformer, PrimaryMeter, UGElectricLineSegment, OHElectricLineSegment |
Yes |
Desktop Server |
ArcFM Update UG Feeder Object |
Combo = Generic Electric Trace Weight + Internal FeederID Update + Check Cross Section |
|
Yes |
Desktop Server |